TRANSFORMERS AND DISTRIBUTION BOARDS
Transformer 600 W
-
in a plastic distribution box, IP 54 shielding
-
230 V / 2 x 12 V toroid transformer
-
two independent windings for two underwater lights 300 W
-
protection of the light with a power breaker
The complete switchboards for protection and control of the filtration unit and other technology and accessories:
a) K - 1S (protection of the lights transformer)
-
the complete switchboards for protection and control of the filtration unit. IP 44 shielding
-
includes: 2/25/0,03 A current protective switch, protection of lights, switching clock with a change over switch of the filtration run (permanent operation, automatic operation, shut down) socket for the direct connection of the filtration unit
b) K2 (el. heating up to 12 kW)
-
the complete switchboards for protection and control of the filtration unit and electrical heating 6, 9, I2 kW and the protection of the 12 V lights transformer with the IP 54 shield
-
includes: 40/4/0,03 A current protective switch, protection of lights, control of the motor, protection of the electrical heating, switching clock with a change over switch of the filtration run (permanent operation, automatic operation, shut down), switching the heating with a control light
-
possibility: blocking the operation by the tariff of the power distributing plant, a control circuit with delayed relay for protection of the heating equipment during fluctuating pressure of the filtration water
c) K2P (el. heating to 12 kW + 3 phase jetswim)
-
the complete switchboards for protection and control of the filtration unit and electrical heating 6, 9, I2 kW, jetswim and the protection of the 12 V lights transformer with the IP 54 shielding
-
includes: 40/4/0,03 A current protective switch, protection of lights, control of the motor, protection of the electrical heating, switching clock with a change over switch of the filtration run (permanent operation, automatic operation, shut down), switching the heating with a control light
-
possibility: blocking the operation by the tariff of the power distributing plant, a control circuit with delayed relay for protection of the heating equipment during fluctuating pressure of the filtration water
d) K3 (exchanger)
-
the complete switchboards for protection and control of the filtration unit, heating by the exchanger and the protection of the 12 V lights transformer with the IP 54 shielding
-
includes: 25/2/0,03 A current protective switch, protection of the motor control, switching clock with heating with a control light and heating protection
e) K4 (exchanger + 3 phase jet swim )
-
the complete switchboards for protection and control of the filtration unit, heating by the exchanger, jetswim, and the protection of the 12 V lights transformer with the IP 54 shielding
-
includes: 40/4/0,03 A current protective switch, protection of lights, control of the motor, protection of the electrical heating, switching clock with a change over switch of the filtration run (permanent operation, automatic operation, shut down), switching the heating with a control light
For more information to other transformer and distribution boards click here 2.0 MB.
In case that you do not have .pdf browser, you can download it free of charge here: